Inspection; Ignition Secondary Coil Resistance; Spark Plug Cap - BRP Johnson 4HP Service Manual

2007
Table of Contents

Advertisement

IGNITION AND ELECTRICAL

INSPECTION

INSPECTION

Ignition Secondary Coil Resistance

Measure the secondary coil resistance in the CDI and coil
unit.
Digital Voltmeter
Tester range: Ω (Resistance)
1. Remove the spark plug cap from the high-tension cord.
2. Measure the secondary coil resistance.
Tester probe connection
Probe
High-tension cord
Ignition secondary coil resistance: 8.2 – 12.4 kΩ
If the measurement is out of the specification, replace the
CDI and coil unit.

Spark Plug Cap

Digital Voltmeter
Tester range: Ω (Resistance)
Measure the spark plug cap resistance.
Tester probe connection
Probe
Cap end
Spark plug cap resistance: 7.5 – 12.5 kΩ
If the measurement is out of the specification, replace the
spark plug cap.
3-4
Other probe
Core
Other probe
Other cap end

Advertisement