6.10 Cleaning the cooking chamber automatically with WaveClean
(optional)
CAUTION
CAUTION
INFORMATION
INFORMATION
INFORMATION
INFORMATION
Risk of chemical burns
Keep the cooking chamber door closed during the cleaning cycle.
Risk of chemical burns
Place the preheat bridge on the lower edge of the cooking chamber opening
on models 20.15 and 20.21 when there is no tray trolley in the combisteamer.
Note regarding cleaning agents
The use of unsuitable cleaning agents normally will damage the units. We
have made a great effort to offer a cleaning agent that provides exceptional
cleaning but does not attack or damage the convection steamer. We thus rec-
ommend that only our own cleaning agent be used. We assume no respon-
sibility or liability for damage caused by unsuitable cleaning agents. Claims
against us cannot be justified on the basis of such damage, not even in the
context of warranty or guarantee.
Cooling the temperature sensor in order to start the cleaning process sooner is
not allowed. The whole cooking chamber must be cooled down to 60 °C (140
°F) for effective cleaning.
Depending on the cleaning level selected, the fan may be idle for up to 60 min-
utes. This does not mean that cleaning has been interrupted; it is a normal part
of the cleaning program.
Forced rinse
Automatic forced rinse is triggered in the following situations.
• Cleaning is canceled manually. Canceling within the first 10 minutes of
cleaning does not trigger an automatic forced rinse.
• Cleaning is canceled automatically in the event of a fault.
• The combisteamer is switched off and then back on during cleaning. An au-
tomatic forced rinse begins when the unit is switched back on.