6.11.4 Drying the cooking chamber

Prerequisite Cooking chamber door closed
INFORMATION

6.12 Swinging the air diverter open and closed

CAUTION
Prerequisite Unit switched off
1. The drying process starts automatically.
The indicator light over the Convection symbol illuminates.
The right display indicates the remaining time.
The cooking chamber is heated.
2. After the end of the drying process, a signal sounds.
"End" appears on the right display.
3. Open the cooking chamber door and leave it ajar until the unit is
used again.
This extends the service life of the door seal.
No moisture builds up in the cooking chamber.
Pinch hazard from rotating fan
• Before working on the unit, ensure that the unit has been disconnected from
the power supply.
• Do not operate the unit without the air diverter.
a
b
c
Image: Air diverter fasteners on countertop and pedestal units
a Air diverter
b Upper fastener
Opening the air diverter
1. Remove the left support rack; present only in size 6 and size 10.
2. Loosen the upper fastener.
3. Loosen the lower fastener.
Operating instructions
Cleaning and caring for the unit
a
b
d
c
c Lower fastener
d Center fastener