Filling The Damper With Nitrogen - Husqvarna FS 450 2015 Repair Manual

Table of Contents

Advertisement

SHOCK ABSORBER, SWINGARM
9
9.25
Filling the dam er with nitrogen
-
Remove adapter
Info
I
Hold the damper so that the filling port is at the highest point.
-
Remove the adapter.
-
Mount and tighten screw Q).
Guideline
I
Screw, filling port
-
Screw in screw
Info
The piston rod is fully extended.
201396-10
-
Clamp the special tool in the vise.
I
Nitrogen filling tool (T170S1)
-
Connect the special tool to the pressure regulator of the filling cylinder.
I
Filling gas - nitrogen
-
Adjust the pressure regulator.
Guideline
I
Gas pressure
-
Position the damper in the special tool.
✓ The hexagonal part of the tap handle f) engages in the hexagon socket of
the filling port screw.
-
Open filler tap (;).
-
Fill the damper for at least 15 seconds.
Guideline
I
Gas pressure
Info
I
Watch the pressure regulator dial.
Make sure that the damper is filled to the specified pressure.
-
Close the filling port screw using tap handle f).
-
Close spigot (;) and take the damper out of the special tool.
-
Tighten the filling port screw.
Guideline
I
Screw, reservoir filling port
O
@>
from connection
of the vacuum pump.
I
M10x1
O
by approx. 2 rotations but do not tighten.
(�
p. 240)
I
10 bar (145 psi)
11 0 bar (145 psi)
67
14 Nm (10.3 lbf ft)
I 3 Nm (2.2 lbf ft)

Advertisement

Table of Contents
loading

Table of Contents