Adjusting the Robacta Reamer Twin lifting device

Adjusting the
It is recommended that one of the following adjustment aids is used to adjust the
lifting device
lifting device:
-
An adjustment aid is not necessary when the gas nozzle is open, as the welding
torch is clamped above the gas nozzle. The gas nozzle can be removed before-
hand. The bracket must be back in the starting position. When the gas nozzle is
mounted, the bracket must be closed.
48
Robacta Twin 900 adjustment aid, item no. 42,0001,5560
(4)
(4)
(4)
Remove the protective cover (1)
1
Ensure that the lifting device is in
2
its lowest lift position
Loosen the screw (2) on the lifting
3
device
Move the welding torch to the
4
cleaning position (including fitted
adjustment aid)
(1)
(1)
Push the lifting device (3) by hand
5
into its highest lift position and
hold in place
(2)
(2)
(3)
(3)
Push the cleaning motor (4) and
6
cleaning cutter by hand into the
cleaning position (5)
(5)
(5)
(5)
NOTE!
The cleaning cutter must not touch
any welding torch components.
Fix the cleaning motor (4) in this
7
position in the lifting device - tight-
en the screw (2) on the lifting
device
Fit the protective cover to the
8
cleaning device in its original posi-
tion