Adjusting the Robacta Reamer Alu 3000upm lift-
ing device
Adjusting the
lifting device
NOTE!
The cleaning cutter must not touch any welding torch components.
8
9
10
11
12
(5)
(5)
(6)
(6)
Fix cleaning motor (4) in this position in the lifting device (3) - tighten screw
(2) on the lifting device
Carry out function test on unfitted gas nozzle - push lifting device by hand to
its highest position
-
The cleaning cutter must close around the contact tip without touching
it. If the cleaning cutter touches welding torch components, readjust the
lifting device
Fit gas nozzle to torch neck
Carry out function test on fitted gas nozzle - push lifting device by hand to
its highest position
-
The cleaning cutter must be inserted into the gas nozzle gently, without
touching it. If the cleaning cutter touches welding torch components, re-
adjust the lifting device
Fit the protective covering to the cleaning device in its original position
Remove protective covering (1)
1
Remove gas nozzle from torch
2
neck
Ensure that the lifting device is in
3
its lowest position
Loosen screw (2) on the lifting
4
device
Move the welding torch to the
5
cleaning position
Push the lifting device (3) by hand
6
into its highest position and hold in
place
Manually push cleaning motor (4)
7
and cleaning cutter to the cleaning
position
-
see diagram (5) for welding
(4)
(4)
torch and spatter guard
(2)
(2)
-
see diagram (6) for welding
(3)
(3)
torch and insulating sleeve