Installing The Robacta Reamer Twin Cleaning Unit; General; Tools Required; Additionally Required - Fronius Robacta TSS /i Operating Instructions Manual

Welding torch cleaning
Table of Contents

Advertisement

3. Installing the Robacta Reamer Twin cleaning unit

General

A Robacta TC 2000 cleaning unit or a Robacta Reamer Twin cleaning unit can be moun-
ted on the service station.

Tools Required

-
-
-
-
-
Additionally
The following accessories are required for installing a Robacta Reamer Twin cleaning
required
unit on the welding torch service station:
OPT/i TSS Reamer Twin ... 4,001,109
Removing the
Injection Device
and Existing
Clamping System
48
Torx screwdriver TX25
3 mm, 5 mm Allen key
Slotted screwdriver
Hammer
18 mm wrench
1
1
2
Loosen 5 Allen screws
1
size 3 mm
Remove the housing casing
2
Disconnect the hose
3
Push the hose inside the device
4
Disconnect the hose
5
Loosen and remove the hexagonal nut
6
inside the device
size 18 mm
3
Remove the injection device
7
7

Advertisement