Care, maintenance and disposal
General
The cleaning device generally needs no maintenance. However, to keep the clean-
ing device in good working condition for years to come, several points on care
and maintenance must be observed.
Before each
-
start-up
-
-
-
-
Daily
Danger from cleaning agents containing solvents.
This can result in damage to property.
▶
1
Weekly
NOTE!
Only use solvent-free cleaning products on the parting agent container.
Only Robacta Reamer Twin:
-
-
Every 6 months
1
As necessary
Open the device and
1
2
3
Disposal
Dispose of in accordance with the applicable national and local regulations.
72
Only Robacta Reamer Twin: Check fill level in parting agent container and
top up if necessary
Check the cleaning cutter / cleaning brushes for wear and replace if neces-
sary
Empty the cleaning device spatter tray
If fitted, empty the wire cutter tray
Perform a general visual inspection on the device
CAUTION!
Only use solvent-free cleaning products on the cleaning device.
Remove parting agent deposits and dirt from device
Check parting agent container for soiling and clean if necessary
Blow through the suction filter in the parting agent container using com-
pressed air from the inside outwards through the suction hose (see "Starting
up the Robacta Reamer Twin parting agent nebuliser")
Open the device and check the pneumatic valves for
-
Leaks
-
The secure seating of all screws
-
The secure seating of all screw joints on the pneumatic valves
Clean inside of device using dry reduced compressed air
Lightly oil the lifting device cylinder guides
Restore the original condition of the device