Hot-Swap Storage Drive Replacement - Inspur NF3180A6 User Manual

Table of Contents

Advertisement

6.
Press and rotate the blue latch 180° clockwise to secure the PCIe riser cage in
place.
7.
Connect the cables of the riser card.
8.
Install the top cover.
4.4.8

Hot-Swap Storage Drive Replacement

For proper cooling, do not operate the server without the top cover, air ducts,
expansion slot covers, or blanks installed. If the server supports hot-swap
components, minimize the amount of time the top cover is open.
To remove the drive:
1.
Remove the hot-swap drive.
a. Press the release latch to release the lever. The lever pops up
automatically.
Figure 4-14 Pressing the Release Latch
b. Hold the lever and pull the drive module out of the drive bay.
36

Advertisement

Table of Contents
loading

Table of Contents