8

Environment Requirements

8.1

Ambient Temperature

Table 8-1 Ambient Temperature
Parameter
Temperature
Humidity
8.2

Vibration and Shock Resistance

Table 8-2 Vibration and Shock Resistance
Parameter
Vibration
Shock
Condition
Continuous operation
Transportation
(Storage)
Maximum temperature
gradient (Operation
and storage)
Operations
Transportation
(Storage)
Condition
Requirement
5-500 Hz: 0.21 Grms (X, Y and Z axis and every
Operation
direction for 15 minutes)
Transportation
5-500 Hz: 2.2 Grms (X, Y and Z axis and every
(Storage)
direction for 10 minutes)
On negative and positive X, Y and Z axis
Operation
direction, each axis can withstand 100
continuous 2 G shock pulses for up to 11 ms
On X, Y and Z axis direction, each axis can
Transportation
withstand 1,000 continuous 40 G shock pulses
(Storage)
for up to 6 ms
Requirement
10°C - 35°C (50°F - 95°F)
-40°C to 70°C (-40°F to 158°F)
20°C/h (36°F/h)
Relative humidity: 10% to 80%
Maximum dew point: 32°C (89.6°F)
When the maximum dew point is 39°C
(102.2°F), relative humidity is 10% to
93%. Atmosphere must be non-
condensing all the time.