Top Cover Replacement - Inspur NF3180A6 User Manual

Table of Contents

Advertisement

4.4.1

Top Cover Replacement

To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool down before touching.
For proper cooling, do not operate the server without the top cover, air duct,
or fans installed.
If the server supports hot-swap components, minimize the amount of time
the top cover is open.
To remove the top cover:
1.
Loosen the screw on the hood latch anticlockwise to the unlocked position with
a Phillips screwdriver.
2.
Lift up the hood latch handle until the top cover slides back and the tabs on
the top cover disengage from the guide slots on the chassis. Hold the top cover
on both sides and remove the panel away from the server.
Figure 4-2 Removing the Top Cover
To install the top cover:
1.
Open the hood latch handle, align the standoffs of the top cover with the J-
slots on the chassis. Lower the top cover down onto the chassis.
2.
Press down the hood latch and then slide the top cover toward the front of the
server until the tabs on the top cover engage with the guide slots on the
chassis, and the hood latch locks into place.