Remove The Motherboard Tray, Psu And 6076 System Fan; Remove The Top Cover And Air Baffle Of The Motherboard Tray - Inspur NF5486M5 User Manual

Hide thumbs Also See for NF5486M5:
Table of Contents

Advertisement

3.
Open the hood latch, place the rear access panel on the server, and align the guide pins
on both sides with the corresponding guide slots on the chassis base.
4.
Align the hole on the hood latch with the alignment pin in the chassis and push the hood
latch to the closed position.

4.6 Remove the Motherboard Tray, PSU and 6076 System Fan

1.
Power down the server.
2.
Extend the server from the rack.
3.
Press the release lever of the motherboard tray, hold the lever and remove the
motherboard tray.
4.
Press the PSU release latch, hold the handle and remove the PSU.
5.
Press the release latcheson both sides of the 6076 system fan and remove the fan.

4.7 Remove the Top Cover and Air Baffle of the Motherboard Tray

CAUTION:To avoid damage to the server, power down the server and remove all AC power
cords before removing or installing the motherboard tray.
1.
Power down the server.
2.
Extend the motherboard tray from the server.
16

Advertisement

Table of Contents
loading

Table of Contents