Battery Replacement - Inspur OB5161M5 User Manual

Table of Contents

Advertisement

7 Battery Replacement

If the server no longer automatically displays the correct date and time, you may need to
replace the battery that provides power to the real-time clock.
WARNING:
The computer contains an internal lithium manganese dioxide, a vanadium
pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is
not properly handled. To reduce the risk of personal injury:
Do not attempt to recharge the battery.
Do not expose the battery to temperatures higher than 60°C (140°F).
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
Replace only with the spare designated for this product.
To remove the component:
1.
Power down the server.
2.
Extend the server from the rack.
3.
Remove the full-length expansion board retainer if any full-length expansion boards are installed.
4.
Remove the PCI riser cage.
5.
Remove the air baffle.
6.
Remove the battery.
To replace the component, reverse the removal procedure.
For more information about battery replacement or proper disposal, contact Inspur Customer Service.
Battery Replacement
105

Advertisement

Table of Contents
loading

Table of Contents