Setup & Operation 6. Options

Mount the brake release unit

(1) Turn OFF the Controller.
(2) If the M/C power cable is not connected to the
(3) Remove the external short connector.
(4) Connect the brake release unit to the connector of the

Remove the brake release unit

(1) Turn OFF the brake release unit.
(2) Remove the power cable of the brake release unit.
(3) Disconnect the brake release unit from the connector of the connection cable.
(4) If the M/C short connector is connected to the M/C power cable, remove the short
(5) Connect the external short connector to the connector of the connection cable.
76
Controller:
Connect the M/C short connector,
or connect the Controller.
(Keep the Controller power OFF)
The M/C short connector can be purchased
singly.
If the M/C power cable is already connected to the
Controller:
Go to the step (3).
connection cable.
conenctor.
External short connector
Connection cable
Connector