Epson C8 Series Manipulator Manual page 150

6-axis robots
Hide thumbs Also See for C8 Series:
Table of Contents

Advertisement

Maintenance 4. Cable Unit
8. Remove the ground wire plate (M/C cable backward).
Hexagon socket head cap bolts: 2-M4×10
9. Remove the ground wire terminals.
Cross recessed head screws with washer
S, C models : 9-M4×8, 2-M3×6
P model
: 10-M4×8, 2-M3×6
10. Remove the brake power supply.
Cross recessed head screws with washer: 2-M3×6
11. Disconnect the following cables through the opening of the base.
D-sub cable
Ground wire
RJ45 connector
F-sensor connector
12. Remove the Joint #1 motor unit.
For details, refer to Maintenance: 5.1.1 Joint #1 - Replacing the Motor (M/C Cable Backward,
Removal steps (6) and (7).
13. Remove the plate for preventing cable interference.
Hexagon socket head cap bolts: 2-M3×6
136
C8 Rev.13