5-2-2-5. Standard Muting Mode with F3W-MA (T-Shaped Configuration with
4-Joint Plug/Socket Connector)
The following is the example of F3SG-RA with Scan Code B, External Device Monitoring disabled,
Auto Reset mode, PNP output and External Test in 24 V Active, and F3W-MA with Scan Code A,
Chattering and Void Space Prevention 1, Off-Delay 100 ms and Muting Enable disabled.
[DIP Switch settings]*1
F3SG-RA
F3W-MA
Primary
F3W-MA
Secondary
Configure functions with the DIP Switches before wiring.
[Wiring Example]
F3W-MA Emitter
S1: Test Switch (Connect the line to 0 V if this switch is not required)
S2: Lockout/Interlock Reset Switch, Override Switch or Override Cancel Switch
ML: Muting lamp
*1. The functions are configurable with DIP Switch. For the DIP Switch of the F3SG-RA, refer to the Chapter 3 Setting with DIP Switch.
For the DIP Switch of the F3W-MA, refer to the Smart Muting Actuator F3W-MA Series User's Manual.
*2. DIP Switch Bank 2 of F3W-MA receiver is not used.
*3. Also used as Override input line.
*4. Make sure to connect an override cancel switch to the Reset line when using the override function. Otherwise the override state may
not be released by the override cancel switch, resulting in serious injury.
*5. Refer to 5-4. Connectable Safety Control Units for more information.
*6. The safety controller and the F3SG-R must share the power supply or be connected to the common terminal of the power supply.
*7. When connecting to the PLC, the output mode must be changed with the Configuration Tool according to your application.
F3SG-R
200
User's Manual
Scan Code B
EDM Disabled (factory default setting)
Receiver
Auto Reset (factory default setting)
PNP (factory default setting)
Scan Code B
Emitter
External Test: 24 V Active (factory default setting)
Scan Code A
Chattering and Void Space Prevention 1
Receiver
Off-Delay 100 ms
Muting Enable Disabled (factory default setting)
Emitter
Scan Code A
Receiver
Emitter
F3W-MA Emitter
(Primary)
(Secondary)
F39-GCN4-L
F39-JG
A-L
S1
Function
No setting
-
required
F3W-MA Receiver
(Primary)
F39-GCN4-D
F39-JG
A-D
S2
*4
IN
Safety
PLC *7
Controller *5 *6
DIP-SW1
DIP-SW2
-
-
-
No setting
required
: Indicates a switch position.
F3W-MA Receiver
(Secondary)
+24 VDC
Power Supply
0 VDC
IN1
IN2
*2
*2
*2
*2
*2
*2