according to the settings of the DIP Switch. When the Position 8 is switched back to ON, the F3SG-RA
operates according to the settings stored in the internal memory.
Note that Scan Code and PNP/NPN Selection are not affected by the Position 8 but by the DIP Switch
setting.

3-2-2. DIP Switch on Emitter

The following functional settings are available by DIP Switches on the emitter. For functional details,
see respective chapter in the Functional Details column.
Position
Function
1
Scan Code
Operating Range
2, 3
Selection
4
External Test
If the power is turned on while the switch is configured as Setting Inhibited, F3SG-RA transitions to lockout.

3-2-3. Push Switch

The F3SG-RA has a Push Switch between the two DIP Switches on the receiver. There is no Push
Switch on the emitter. The Push Switch is used to make the settings to the Fixed Blanking and Floating
Blanking by the Teach-in.
Refer to 3-3. Setting by Teach-in for more information.
Setting
Description
Scan Code A (factory default
setting)
Scan Code B
Short Mode
Setting Inhibited
Setting Inhibited
Long Mode (factory default setting)
24 V Active (factory default setting)
0 V Active
Setting with DIP Switch
: Indicates a switch position.
Functional
Details
2-4
2-4
2-21
-
-
2-21
2-7
2-7
E
F3SG-R
113
User's Manual