Setting with DIP Switch

3-2-1. DIP Switch on Receiver

The following functional settings are available by DIP Switches on the receiver. A receiver has two DIP
Switches, both of which must be configured based on the table below. For functional details, see
respective chapter in the Functional Details column.
If the settings of two DIP Switches are different, when the power is turned on, F3SG-RA transitions to lockout.
Position
1
2
3, 4
5, 6
7
8
You can configure the receiver's DIP Switch position 8 whether the setting of the DIP Switch or the
Configuration Tool should be enabled. If you want to use the Configuration Tool to change the setting,
configure the Position 8 setting as Configuration Tool Enabled. This setting ignores the DIP Switch
setting.
Settings changed with the Configuration Tool are stored in the internal memory of the F3SG-RA. When
any change is made to the settings and then the Position 8 is set to OFF, the F3SG-RA operates
F3SG-R
112
User's Manual
Function
DIP-SW1
Scan Code
External Device
Monitoring (EDM)
Interlock/Pre-Reset
Fixed Blanking/
Floating Blanking
PNP/NPN Selection
DIP Switch/
Configuration Tool
Selection
: Indicates a switch position.
Setting
DIP-SW2
Scan Code A (factory default
setting)
Scan Code B
External Device Monitoring (EDM)
Disabled (factory default setting)
External Device Monitoring (EDM)
Enabled
Auto Reset (factory default setting)
Manual Reset
(Start/Restart Interlock)
Pre-Reset
Auto Reset (same as factory default
setting)
Blanking Disabled (factory default
setting)
Fixed Blanking Enabled
Floating Blanking Enabled
Blanking Disabled
(Same as Blanking Disabled
(factory default setting))
PNP (factory default setting)
NPN
DIP Switch Enabled (factory default
setting)
Configuration Tool Enabled
Functional
Description
Details
2-4
2-4
2-11
2-11
2-9
2-9
2-10
2-9
-
2-15
2-16
-
2-5
2-5
See below.
See below.