Input/Output Circuit and Applications

5-2-1-3. Y-Joint Plug/Socket Connector using PNP outputs

The following is the example of Muting not used, External Device Monitoring enabled, Manual Reset
mode, PNP output and External Test in 24 V Active.
[DIP Switch settings] *3
Receiver
Emitter
Configure functions with the DIP Switches before wiring.
[Wiring Example]
S1: Lockout/Interlock Reset Switch
KM1,KM2: External device feedback
M: 3-phase motor
PLC: Programmable controller
(Used for monitoring only. NOT related to safety system.)
F3SG-R
194
User's Manual
Function
EDM Enabled
Manual Reset
PNP (factory default setting)
External Test: 24 V Active (factory default setting)
F39-GCNY2
F39-JG B-L
S1
KM1
KM2
Unblocked
Beam state
Blocked
Reset Switch (S1)
OSSD
DIP-SW1
F39-JG A-D
KM1
KM2
*1. Also used as EDM input line.
IN
*2. When connecting to the PLC, the output mode must be
changed with the Configuration Tool according to your
application.
PLC *2
*3. The functions are configurable with DIP Switch. Refer to
Chapter 3 Setting with DIP Switch for more information on
setting the functions by the DIP Switch.
DIP-SW2
: Indicates a switch position.
KM1
KM2
+24 VDC
Power supply
0 VDC
M