Double-Ended Cable - Omron F3SG-2RE0430P30 User Manual

Safety light curtain
Table of Contents

Advertisement

Wiring/Installation
Emitter cable (Gray)
F39-JG3A-L
F39-JG7A-L
F39-JG10A-L
F39-JG15A-L
F39-JG20A-L

4-5-3-2. Double-Ended Cable

 Double-Ended Cable for Emitter: Cable for extension (F39-JGB-L, sold separately)
<Internal wiring diagram>
Connected to Power Cable
or Double-Ended Cable
1
2
5
4
3
Female
Twisted pair wires are brown and blue, and white and yellow.
F3SG-R
168
User's Manual
Receiver cable (Black)
F39-JG3A-D
F39-JG7A-D
F39-JG10A-D
F39-JG15A-D
F39-JG20A-D
44.7
M12 IP67 connector
Insulated vinyl round cable dia. 6.6, 5-wire (2-pair + 1)
(Cross section of conductor: 0.38 mm
1
Brown
3
Blue
2
Black
4
White
5
Yellow
L (m)
3
7
10
15
20
L
M12 IP67 connector
2
/insulator diameter: dia. 1.2 mm)
Connected to Single-Ended Cable, or
Double-Ended cable
1
Brown
3
Blue
2
Black
4
White
5
Yellow
(Unit: mm)
40.7
2
1
5
3
4
Male

Advertisement

Table of Contents
loading