2-11-4. Setting with Configuration Tool
Some settings of functions configurable with the Configuration Tool may increase risks.
Make sure the Responsible Person conduct a thorough risk assessment analysis before
managing and changing the settings. Unintended changes to the settings may cause a
person to go undetected, resulting in serious injury.
The user can make changes to the settings by the Configuration Tool.
• Output operation mode
Information to be allocated to the auxiliary output
• Inverted signal output mode
Auxiliary output gives a inverted signal of the safety output.
• Output pattern
Pattern to send an output signal from the auxiliary output
The user can make changes to the settings by the Configuration Tool.
Function
Output operation mode
Inverted signal output
Output pattern
*1. Setting parameters of this function can be saved according to the states where the Muting function
is enabled and disabled, respectively. After changing the Muting function from Enable to Disable or
from Disable to Enable, also check the settings of this function again.
Refer to
Considerations for enabling and disabling Muting function under 2-1. Combination of
Functions for more information.
Refer to 2-12. Muting for more information on settings of the Muting function.
*2. Refer to the table of Information (Output operation mode) assigned to auxiliary output below.
*3. Output signal is sent according to the patterns as shown in the output pattern chart below.
 Output pattern chart
ON 1 time
Solid-ON
Factory Default Setting
Muting function *1
Enabled
Safety output information
Enable
Solid-ON
1 s
System Operation and Functions
Disabled
Safety output information
*2
Enable
Enable/Disable
Solid-ON
Solid-ON/ON 1 time *3
Available Parameters
F3SG-R
User's Manual
E
45