Checklists
When the ON/OFF indicator is green and the F3SG-RA is blocked and then returned to unblocked
state, the ON/OFF indicator remains red. The RESET input turns the ON/OFF indicator to green.
When muting function is used, minimum muting time limit required must be set.
When muting function's operation mode is exit-only muting mode, minimum muting end wait time
required must be set.
Under muting state, a signal that indicates muting state must be output from the Auxiliary Output.
When override function is used, minimum override time limit required must be set.
Under override state, a signal that indicates override state must be output from the Auxiliary Output.

6-1-1-4. Checking that Hazardous Parts Stop While the Machine Operates

The hazardous parts stop immediately when a test rod is inserted into the detection zone at 3
positions: "directly in front of the emitter", "directly in front of the receiver", and "between the emitter
and receiver". (Use the appropriate test rod.)
The hazardous parts remain stopped as long as the test rod is in the detection zone.
The hazardous parts stop when the power of the F3SG-R is turned OFF.
The actual response time of the whole machine is equal to or less than the calculated value.