Omron F3SG-2RE0430P30 User Manual page 196

Safety light curtain
Table of Contents

Advertisement

Wiring/Installation
 Emitter Adapter Cable (A) (F39-JGR3M-A55-L, sold separately)
<Internal wiring diagram>
Connected to connector of MS4800
transmitter cable
0 VDC
+24 VDC
(MTS)
(MTS Return)
(Earth)
 Receiver Adapter Cable (A) (F39-JGR3M-A88-D, sold separately)
<Internal wiring diagram>
Connected to connector of MS4800
receiver cable
+24 VDC
0 VDC
(Earth)
OSSD 2
Start or EDM (Mode Select)
(EDM)
Auxiliary Out
OSSD 1
F3SG-R
172
User's Manual
44.7
M12 IP67 connector, 5-wire
2
5
3
Male
MS4800
1
2
3
-
4
-
-
5
44.7
M12 IP67 connector, 8-wire
MS4800
Brown
1
Blue
2
-
3
White
4
Yellow
5
-
6
Red
7
Black
8
300
Insulated vinyl round cable dia. 6-mm
1
4
Emitter Adapter Cable (A)
1
1
2
2
3
3
4
4
5
5
300
Insulated vinyl round cable dia. 6-mm
2
1
7
3
8
4
6
5
Receiver Adapter Cable (A)
Male
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
(Unit: mm)
40.7
M12 IP67 connector, 5-wire
1
2
5
4
3
Connected to Power Cable or
Double-Ended Cable of F3SG-RA emitter
Female
F3SG-RA
1
+24 VDC
2
-
(TEST)
3
0 VDC
4
-
(Not used)
5
-
(Not used)
(Unit: mm)
40.7
M12 IP67 connector, 8-wire
1
2
3
7
8
6
4
Connected to Power Cable or
5
Double-Ended Cable of F3SG-RA receiver
Female
F3SG-RA
1
Yellow
RESET
+24 VDC
2
Brown
3
-
(MUTE A)
(MUTE B)
4
-
5
Black
OSSD 1
OSSD 2
6
White
7
Blue
0 VDC
8
Red
AUX