Checking That Hazardous Parts Stop While The Machine Operates; Items To Inspect Every 6 Months Or When Machine Settings Are Changed - Omron F3SG-2RE0430P30 User Manual

Safety light curtain
Table of Contents

Advertisement

Checklists
The test rod is detected when it is moved around in the detection zone as shown in the diagram below.
In other words, when a test rod is inserted into the detection zone, the Stable-state indicator turns
OFF and the ON/OFF indicator turns red.
When fixed blanking function is used, you must ensure that all blanked zones in the detection zone
are covered by a hard barrier guard and there must be no zone in the detection zone where the test
rod goes undetected.
The object resolution may vary depending on the models of the F3SG-R and settings of floating
blanking function or reduced resolution function. Use a test rod with an appropriate diameter for
inspection. A test rod is not included in the F3SG-R product package.
Confirm that hazardous parts should stop while the machine is operating, as shown below.
When muting function is used, installation condition of muting sensor must not be changed.
When muting function is used, muting status can be checked from where a worker operates or adjust
the machine.
Neither connector, cap, or bracket must be loose.

6-2-1-2. Checking that Hazardous Parts Stop While the Machine Operates

The hazardous parts are movable when nothing is in the detection zone.
The hazardous parts stop immediately when a test rod is inserted into the detection zone at 3
positions: "directly in front of the emitter", "directly in front of the receiver", and "between the emitter
and receiver". (Use the appropriate test rod.)
The hazardous parts remain stopped as long as the test rod is in the detection zone.
The hazardous parts stop when the power of the F3SG-R is turned OFF while nothing is in the
detection zone.

6-2-1-3. Items to Inspect Every 6 Months or When Machine Settings Are Changed

In addition to inspection item at operation start, following items must also be verified.
The outputs of the F3SG-R and the machine are properly wired.
The total number of times that the control relays/contactors have switched is significantly lower than
their design lives.
There is no ambient light.
Safety distance has been calculated with changed object resolution when the setting of the floating
blanking or reduced resolution function is changed.
Calculated distance: S = (
When muting function setting is changed, a muting sensor must be installed so that muting state
should not occur when a human body enters a detection zone of F3SG-RA by mistake.
F3SG-R
218
User's Manual
Start
Stop
)mm