System Operation and Functions
2-4. Scan Code Selection
F3SG-RA Series
F3SG-RE Series
2-4-1. Overview
The F3SG-RA has two scan codes (Code A and Code B). These scan codes have different internal
processing time. The use of different scan codes allows for placement of systems in close proximity
and in line with each other and minimize mutual interference.
The response time for Code A is 1 ms shorter than that for Code B.
The Scan Code Selection is not available for the F3SG-RE.
1-6-1. List of Models/Response Time/Current Consumption/Weight for more information on the response
time.
Refer to 4-1-4. Mutual Interference Prevention for how to mitigate mutual interference.
2-4-2. Factory Default Setting
The factory default setting is Code A.
Both the emitter and receiver units must be set to the same code.
2-4-3. Setting with DIP Switch
The user can select the scan code from Code A or Code B by the DIP Switch.
Refer to Chapter 3 Setting with DIP Switch for more information on setting this function by the DIP Switch.
2-4-4. Setting with Configuration Tool
The user cannot make any changes to the scan code by the Configuration Tool.
F3SG-R
28
User's Manual
X