5-2-1-2. Manual Reset Mode, EDM enabled and PNP Outputs

The following is the example of Muting not used, External Device Monitoring enabled, Manual Reset
mode, PNP output and External Test in 24 V Active.
[DIP Switch settings] *2
EDM Enabled
Receiver
Manual Reset
PNP (factory default setting)
Emitter
External Test: 24 V Active (factory default setting)
Configure functions with the DIP Switches before wiring.
[Wiring Example]
F39-JG A-L
S1
+24 VDC
Power Supply
0 VDC
Function
F39-JG A-D
S2
KM1
KM2
S1: Test Switch (Connect the line to 0 V
if this switch is not required)
S2: Lockout/Interlock Reset Switch
KM1, KM2: Safety relay with forcibly guided contacts (G7SA)
or magnetic contactor
M: 3-phase motor
*1. Also used as EDM input line.
*2. The functions are configurable with DIP Switch. Refer to
Chapter 3 Setting with DIP Switch for more information on
setting the functions by the DIP Switch.
Unblocked
Beam state
Blocked
Test Switch (S1)
Reset Switch (S2)
OSSD
Input/Output Circuit and Applications
DIP-SW1
DIP-SW2
: Indicates a switch position.
KM1
KM2
KM1
KM2
M
E
F3SG-R
193
User's Manual