2-7. External Test

F3SG-RA Series
F3SG-RE Series

2-7-1. Overview

This function stops the emission using an external signal. It can be used to verify that a safety system
should properly stop (safety output turns OFF) when F3SG-RA is blocked.
To stop the emission, apply the following voltage to the emitter's TEST input line according to the DIP
switch settings of the emitter.
When muting, safety output is kept ON even if the emission is stoped.
DIP Switch settings
(Position 4 on Emitter)
Input voltage
The External Test is not available for the F3SG-RE.
<Basic wiring diagram>
+24 VDC
Power Supply
0 VDC
F3SG-R
32
User's Manual
X
24 V Active
9 V to Vs
24 V Active
F39-JG A-L
S1
S1: Test Switch (Connect the line to
0 V if this switch is not required)
0 V Active
0 to 3 V
0 V Active
+24 VDC
Power Supply
S1
0 VDC
S1: Test Switch (Connect the line to
24 V if this switch is not required)
F39-JG A-L