Table 5-8 No Beam Emitted After Hv And Gun Are Switched On - ferrotec Temescal CV-12SLX User Manual

Table of Contents

Advertisement

5.4 Troubleshooting Procedures
Before performing any of the procedures described on this page, perform the
procedure described in section 5.4.1.

Table 5-8 No Beam Emitted After HV and Gun Are Switched On

Symptom: HV and gun are switched on, but no beam is emitted
For additional information about this fault mode, see Ishikawa Diagram #3.
Possible Causes
1. Faulty or loose connections.
2. Confirm HV Ready signal
3. Confirm Gun Ready signal
4. Emitter damaged
5. Confirm HV IS ON signal
6. Confirm GUN IS ON signal
7. Fault conditions whose investigation
requires removal of FPS top cover.
Before performing the following procedure, perform the procedure described in
section 5.4.3.
Symptom: HV fluctuates or sags from requested level
For additional information about this fault mode, see Ishikawa Diagram #4.
Possible Causes
1. Incorrect or fluctuating line voltage
2. Faulty or loose cable connections.
3. Emitter damaged
4. System incorrectly grounded for HV
If the preceding steps have failed to correct the fault, perform the following procedure:
1. Switch off the power supply.
2. Disconnect HV output cable.
3. Switch on the power supply and the HV and leave them switched on for no more than 9 seconds, observing whether the
symptom persists during that interval.
DO NOT leave the high voltage on for more than 9 seconds with the HV cable disconnected. Doing so will
result in the emitter's filament burning out.
CV-12SLX User Manual
DANGER: HIGH VOLTAGE
1. Make sure that all HV and FPS connections are correctly and securely made.
2. See Table 5-3.
3. See Table 5-4.
4. Follow instructions in gun manual to troubleshoot emitter issues.
5. See Table 5-5.
6. See Table 5-6.
7. Contact Temescal Field Service
DANGER: HIGH VOLTAGE
Table 5-9 HV Output Unstable
1. Confirm input line voltage
2. Make sure that all power module and FPS cable connections are
correctly and securely made.
3. Follow instructions in gun manual to troubleshoot emitter issues.
4. Make sure that grounding instructions in e-gun manual have been
correctly implemented.
CAUTION
5-20
Procedure
.
Procedure
Section 5: Troubleshooting
0101-8292-0, Rev. C

Advertisement

Table of Contents
loading

Table of Contents