Table 5-6 Fps Powered Up But Gun Does Not Switch On When Commanded To Do So; Table 5-7 No Filament Current After Gun On State Is Achieved - ferrotec Temescal CV-12SLX User Manual

Table of Contents

Advertisement

Section 5: Troubleshooting
Before performing any of the procedures described on this page, perform the
procedure described in section 5.4.1.

Table 5-6 FPS Powered Up but Gun Does Not Switch On When Commanded To Do So

Symptoms
TCS displays SRC1_GON_ALM (= Source 1 Control Go On Timeout Alarm)
Remote Controller: Gun Ready light inside Gun Control panel's OFF button fails to light
EBC issues FPS Gun Ctl Go On Timeout alarm
Possible Causes
1. Faulty or loose cable connections.
2. Confirm Gun Ready signal
3. Emitter damaged
If the preceding steps have failed to correct the fault, perform the following procedure:
1. Switch off the power supply.
2. Disconnect HV output cable.
3. Switch on the power supply and the HV and leave them switched on for no more than 9 seconds, observing whether the
symptom persists during that interval.
DO NOT leave the high voltage on for more than 9 seconds with the HV cable disconnected. Doing so will
result in the emitter's filament burning out.
4. If the symptom is not in evidence during Step 3, troubleshoot the HV path and emitter assembly, following the instructions
in the e-gun manual. If the symptom persists during Step 3, reconnect the HV output cable to J101, switch the power
supply back on, and proceed with the troubleshooting steps described below.
4. Fault conditions whose investigation
requires removal of FPS top cover.

Table 5-7 No Filament Current After GUN ON State Is Achieved

Symptom: Gun switches on but has no filament current
Possible Causes
1. Faulty or loose cable connections.
2. Emitter damaged
3. Incorrect filament bias current
4. FPS fault
5. Fault conditions whose investigation
requires removal of FPS top cover.
0101-8292-0, Rev. C
DANGER: HIGH VOLTAGE
1. Make sure that all power module and FPS cable connections are correctly
and securely made.
2. See Table 5-4.
3. Follow instructions in gun manual to troubleshoot emitter issues.
CAUTION
4. Contact Temescal Field Service
1. Make sure that all power module and FPS cable connections are
correctly and securely made.
2. Follow instructions in gun manual to troubleshoot emitter issues.
3. Adjust filament bias current
4. See Tables 5-23, 5-24, and 5-25.
5. Contact Temescal Field Service
5-19
5.4 Troubleshooting Procedures
Procedure
.
Procedure
.
CV-12SLX User Manual

Advertisement

Table of Contents
loading