Figure 2-6 Grounding Studs On Fps Front Panel - ferrotec Temescal CV-12SLX User Manual

Table of Contents

Advertisement

2.5 Grounding Requirements
2.5.4 Filament Power Supply Grounding
Make connections to the grounding lugs on the FPS front panel as shown in one of the Quick
Start Guides for the CV-12SLX, following the procedure described below.
CV-12SLX User Manual
3
Secure a length of #10 AWG wire to the grounding lug labeled GND
on the power module rear panel.
4
Secure the loose end of the 1/2" copper strip and the loose end of
the #10 AWG ground wire to a clear, bare patch of metal on the
operator station's frame. The same fastener that secures the above
copper strip to the frame should also secure one end of a length of
3" copper strap that connects to the vacuum cubicle's central
grounding point, as shown in Figure 2-3.
Step
Action
1
Cut a length of 1/2"-wide copper strap (user-supplied) that will
easily extend from the filament power supply to the vacuum
cubicle's central grounding point.
2
Secure one end of this strap to the grounding stud labeled RF GND
on the FPS front panel (see Figure 2-).

Figure 2-6 Grounding Studs on FPS Front Panel

3
Secure a length of #10 AWG wire to the other grounding lug on the
FPS front panel.
4
Secure the free ends of the 1/2" copper strip and the #10 AWG
ground wire to the vacuum cubicle's central grounding point.
2-8
Section 2: Installation
RF Ground. Connect to vacuum
cubicle's central gounding point,
using 1/2"-wide copper strap (PN
5621-0032-0).
Chassis Ground. Connect to vacuum
cubicle's central gounding point, using
#10 AWG wire.
0101-8292-0, Rev. C