Section 2: Installation
Table 2-1 Descriptions of I/Os Exchanged via HVPS Rear Panel
Signal Name
KV SET IN
ANALOG COMMON
KV MONITOR OUT
mA MONITOR OUT
REMOTE/LOCAL IN
I/O SWITCHES POWER
DIGITAL COMMON
HV ON IN +
HV ON IN –
RESET +
RESET –
HV IS ON INDICATOR
POWER SUPPLY FAULT
INDICATOR
HV READY INDICATOR
OUT OF REGULATION
INDICATOR
INTERLOCK OK INDICATOR
HV OFF IN+
HV OFF IN–
REMOTE INTERLOCKS IN
REMOTE INTERLOCKS OUT
0101-8292-0, Rev. C
Connector J4 and the HVPS I/O Cable (PN 0620-6682-0)
Pin I/O Type Description
1
Analog
HV adjustment input, 0-10 V dc = 0-10 KV. Controls high voltage if Pin 5 is high, in
input
which case the HVPS front panel OUTPUT kV ADJUST pot is disabled.
2
Analog
Common for KV MONITOR OUT and mA MONITOR OUT outputs (see Pins 3 and 4), if
common
used. Connect to vacuum system ground.
3
Analog
High voltage monitor output, linear (0-10 V dc = 0-10 kV).
output
4
Analog
Emission current monitor output., linear. Scaling is factory set (0-10 V dc = 0-1500 mA).
output
5
Digital
Selects either remote or local HV control. If high, (i.e., if +24 V dc is supplied), then 0-
input
10 dc input via Pin 1 controls HV exclusively. If low, then HVPS front panel OUTPUT kV
ADJUST pot exclusively controls the high voltage.
6
DC voltage + 24 V dc output, fused at 1 A. Can be used to supply Pin 5, if remote HV control via
Pin 1 is desired. NOTE: To be used only for power supply control; do NOT use this
voltage to drive any external device.
7
Digital
Common for digital indicator signals output via Pins 12, 13, 14, 15, and 16, if any of
common
them are used.
8
Digital
Controlled by a normally open external switch. If HV OFF IN + is high, then a
input
momentary contact closure between Pins 8 and 9 switches the high voltage ON.
9
DC voltage + 15 dc output supplied to Pin 8 via a normally open switch.
10
Digital
Controlled by a normally open external switch. If the POWER SUPPLY FAULT
input
INDICATOR output (Pin 13) is true, then a momentary contact closure between Pins 10
and 11 resets the HVPS.
11
DC voltage + 24 dc output supplied Pin 10 via a normally open switch controlling.
12
Digital
When high (+24 V dc), this output indicates that the high voltage is ON.
output
13
Digital
When high, this output indicates that a latching power supply fault has occurred. For
output
additional details about latching PS faults, see section 5.2.
14
Digital
When high, this output indicates that the HV can be switched on. This indicator is high
output
when the HV OFF IN+ input supplied via Pin 17 is high.
15
Digital
High whenever the HVPS front panel HV OUT OF REGULATION LED is lit. For additional
output
details about that LED, see section 5.2.
16
Digital
High when all interlocks are made, so that the REMOTE INTERLOCK IN input (Pin 24) is
output
high.
17
Digital
Controlled by a normally closed external switch. This input is high when the HV is OFF
input
and when no latching power supply faults exist. When the HV is ON, then momentary
opening of the external contact closure between Pins 17 and 18 switches off the HV.
18
DC voltage + 15 dc output supplied to Pin 17 via a normally closed switch.
24
Digital
High when the external interlock string is made; connect to Pin 24 via external interlock
input
switches.
25
DC voltage + 24 dc output, fused at 0.2 A and supplied to Pin 24 via external interlock switches.
NOTE: Minimum external interlocks required are WATER (= e-beam gun's water-flow
switch is true), DOORS (= all vacuum cubicle doors are closed), and VACUUM (=
vacuum system is pumped down to crossover point). If e-beam position is controlled by
a beam sweep controller, a POSITION interlock signal from that component must also
be true. NOTE: Within the HVPS, the external interlock string is connected in series with
the internal interlocks for the HVPS and FPS covers.
2-17
2.6 Cable Installation