Section 5: Troubleshooting

Ishikawa Diagram #5: HV Out of Regulation LED Lights Frequently

Emitter
Dirty/loose connections

Ishikawa Diagram #6: Arc/Out of Regulation LED Lights Excessively for the Material/Application

Damaged emitter
HV relay shorting
Faulty/loose cable
Connections
FPS
0101-8292-0, Rev. C
Possible Causes
Emitter damaged
HV Path
Possible Causes
Other
Short in HV path
Improper grounding
Short in HV path
Shorts/loose connections on HV
feedthrough(s) or HV connection path
Faulty/loose cable
connections
Incorrect line voltage;
or phasemissi n g
Improper grounding
Mains
5-9
5.3 Ishikawa Diagrams
Consequence
HV Out of Regulation
LED lights frequently
(see Table 6-11)
Consequence
Arc/Out of Regulation LED
flashes excessively for the
material/application
(see Table 6-11)