Figure 2-9 Input Power And Hv Connections On Fps Front Panel - ferrotec Temescal CV-12SLX User Manual

Table of Contents

Advertisement

Section 2: Installation

Figure 2-9 Input Power and HV Connections on FPS Front Panel

FPS ON/OFF Switch
Plug 208-V power cable
(PN 6622-0100-20) in here.
2.6.2 Connecting the HV Coaxial Cable(s) (PN 0620-8684-1)
The HV coaxial cable (PN 0620-8684-1) conducts the high voltage output of the power module
to the FPS module(s). In one-gun installations, plug one end of this HV cable into HVPS rear
panel connector J7 (see Figure 2-4). In two-gun installations, plug the HV cable for FPS #1
into J7 and the HV cable for FPS #2 into J8 (see Figure 2-5). Connect the other end of each
HV cable to the HIGH VOLTAGE IN connector on the FPS front panel (see Figure 2-).
2.6.3 Connecting the HV Output Conduit(s) (PN 0620-9654-1)
The cables that conduct the high voltage from the FPS to the source tray are contained in a
length of flexible conduit. The part number of the HV cable/conduit assembly is 0620-9654-1.
The instructions below describe how to install the HV conduit in a single-gun installation. In a
dual-gun installation, the only additional step is determining which gun will be designated as
gun #1. The HV conduit for that gun should be connected to the FPS module that has been
designated as FPS #1.
Connecting the HV Output Cables and Conduit to the FPS
Connect the HV cable/conduit assembly to the FPS rear panel (see Figure 2-), following the
procedure described below.
0101-8292-0, Rev. C
Step
Action
1
Remove four screws that secure the conduit panel to the FPS rear
panel, as shown below.
2-11
2.6 Cable Installation
Plug one end of HV coaxial
cable (PN 0620-8684-1) in here.
CV-12SLX User Manual