2.2 List of Components and Cables Supplied with the Unit

2.2
List of Components and Cables Supplied with the Unit
2.2.1 Single-gun units
Listed below are the components and cables supplied with single-gun CV-12SLX units.
One CV-12SLX HVPS, PN 0620-1115-0 (= 208-volt unit) or 0620-1125-0 (= 400-volt unit)
One filament power supply, PN 0620-6604-0
One FPS input power cable, PN 6622-0100-20
One HVPS-FPS cable, PN 0620-6672-0
One FPS I/O cable, PN 0620-6672-2
One HVPS I/O cable, PN 0620-6682-2
One HV coaxial cable, PN 0620-8684-1
One HV cable/conduit assembly, PN 0620-9654-1
One bracket (PN 0040-9982-0) for securing HV conduit to HV feedthroughs source tray
One 16" grounding hook, PN 9900-4864-0
One 20' coil of 3"-wide copper strap, PN 5621-0032-3
One coil of ½"-wide copper strap, PN 5621-0032-0
One connector for connecting a user-supplied AC input power cable to the HVPS
One copy of the CV-12SLX Technical manual
2.2.2 Dual-gun units
Listed below are the components and cables supplied with dual-gun CV-12SLX units.
One CV-12SLX HVPS, PN 0620-1115-1 (= 208-volt unit) or 0620-1125-1 (= 400-volt unit)
Two filament power supply modules, PN 0620-6604-1
Two FPS input power cables, PN 6622-0100-20
Two HVPS-FPS cables, PN 0620-6672-0
One FPS I/O cable, PN 0620-6672-2
One HVPS I/O cable, PN 0620-6682-2
Two HV coaxial cables, PN 0620-8684-1
Two HV cable/conduit assemblies, PN 0620-9654-1
Two brackets (PN 0040-9982-0) for securing HV conduits to HV feedthroughs on source
tray
One 16" grounding hook, PN 9900-4864-0
One 20' coil of 3"-wide copper strap, PN 5621-0032-3
One coil of ½"-wide copper strap, PN 5621-0032-0
One connector for connecting a user-supplied AC input power cable to the HVPS
One copy of the CV-12SLX Technical manual
2.3

Rack Mounting the Power Module (HVPS)

2.3.1 General Installation Guidelines
The CV-12SLX HVPS can be rack mounted in a standard 19" rack cabinet. It must be
supported by two side shelf supports to hold the power supply weight. The rack vertical height
required is 8-3/4 inches. The chassis depth is 23 inches. An additional 3" is required for
clearance of terminals, plugs, and wiring. The panel should be secured to the rack cabinet by
the four mounting holes provided.
CV-12SLX User Manual
2-2
Section 2: Installation
0101-8292-0, Rev. C