Program Example When 2 Stations Are Occupied - Mitsubishi Electric MELSERVO-J3 Series Instruction Manual

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

3. CC-LINK COMMUNICATION FUNCTIONS

3.8.4 Program example when 2 stations are occupied

Operate the servo amplifier of station 1 in the positioning mode and read the "motor speed" data.
Preset the parameter No.PC30 to "
Operation: Alarm reset, dog type home position return, JOG operation, automatic operation under point table
command
Code No.
H0016
32-bit data of motor speed (hexadecimal)
Code No.
K50000
Position command data (decimal)
K100
Speed command data (decimal)
Reset command
Servo-on command
Automatic/manual selection
Automatic/manual selection
Home position return
Home position return completion
command
Proximity dog command
Forward rotation JOG command
Reverse rotation JOG command
POINT
To execute a dog type home position return with the CC-Link communication
functions, set " 0
" in parameter No.PD14 and use Proximity dog (DOG)
with RY03 in this example.
2".
Description
Description
3 - 59
Checks data link status of station No.1.
Writes current alarm read (H0010) to RWw2 at
trouble (RX3A) occurrence.
Turns on instruction code execution demand
(RY09).
Reads current alarm (RWr3) and respond code
(RWr2) to D11 and D12 when instruction code
execution completion (RX09) turns on.
Turns off instruction code execution demand
(RY09).
Alarm reset command (RY3A)
Servo-on command (RY00)
Automatic operation mode selection (RY06)
Manual operation mode selection (RY06)
Home position return request
Point table establishment time 4ms *1
Forward rotation start request
Command request time 6ms *1
Forward rotation start request reset
Proximity dog command (RY03)
Forward rotation start request
Reverse rotation start request