14. OPTIONS AND AUXILIARY EQUIPMENT
Cable model
MR-J3ENSCBL
Receptacle: 36210-0100PL
M-L
Shell kit: 36310-3200-008
(3M)
2
LG
1
P5
View seen from wiring side. (Note)
Connector set: 54599-1019
MR-J3ENSCBL
(Molex)
M-H
2
LG
1
P5
View seen from wiring side. (Note)
Note. Keep open the pins shown with
MR-J3ENSCBL
provided for manufacturer
M-L-S06
adjustment. If it is connected
with any other pin, the servo
amplifier cannot operate
normally. Referring to section
4.9, securely connect the
external conductor to the
ground plate and fix it to the
connector shell.
MR-J3ENSCBL
M-H-S06
1) CN2 side connector
6
10
4
8
MRR
5
9
3
7
BAT
MR
or
4
6
8
10
MRR
3
5
7
9
MR
BAT
. Especially, pin 10 is
2) Encoder side connector
Cable
Bending life
length
Long
10m or
bending life
less
Standard
CMV1-SP10S-M1
Long
20m or
bending life
more
Standard
CMV1-SP10S-M2
7
View seen from wiring side. (Note)
Note. Keep open the pin shown with an
Cable
Bending life
length
Long
10m or
bending life
less
Standard
CM10-SP10S-VP-M
Long
20m or
bending life
more
Standard
7
View seen from wiring side. (Note)
Note. Keep open the pin shown with an
14 - 18
Plug (DDK)
Straight plug
Socket contact
CMV1-#22ASC-C1-100
Applicable wire size: AWG24 to
20
Crimping tool: 357J-53162T
CMV1-#22ASC-C2-100
Applicable wire size: AWG28 to
24
Crimping tool: 357J-53163T
3
2
1
MRR
MR
6
5
4
LG
BAT
10
9
8
SHD
P5
.
Plug (DDK)
Straight plug
Socket contact
CM10-#22SC(C1)(D8)-100
Applicable wire size: AWG22 to
20
Crimping tool: 357J-50446
CM10-#22SC(C2)(D8)-100
Applicable wire size: AWG28 to
23
Crimping tool: 357J-50447
3
2
1
MRR
MR
6
5
4
BAT
LG
10
9
8
SHD