17. SPEED CONTROL OPERATION
Code No.
8601h
Servo motor speed data RAM command of point
to
table
8608h
Writes the servo motor speed of point table No. 1 to
8 to RAM. These values are cleared when power is
switched off.
The decimal value converted from the lower two
digits of the code No. corresponds to the point table
No.
8701h
Acceleration time constant data RAM command of
to
point table
8702h
Writes the acceleration time constants of point
table No.1 and 2 to RAM. These values are cleared
when power is switched off.
The decimal value converted from the lower two
digits of the code No. corresponds to the point table
No.
8801h
Deceleration time constant data RAM command of
to
point table
8802h
Writes the deceleration time constants of point
table No.1 and 2 to RAM. These values are cleared
when power is switched off.
The decimal value converted from the lower two
digits of the code No. corresponds to the point table
No.
8D01h
Servo motor speed data EEP-ROM command of
to
point table
8D08h
Writes the servo motor speed of point table No.1 to
8 to EEP-ROM. The values are written to
EEP-ROM and therefore stored even if the power is
switched off.
The decimal value converted from the lower two
digits of the code No. corresponds to the point table
No.
8E01h
Acceleration time constant data EEP-ROM
to
command of point table
8E02h
Writes the acceleration time constant No. of point
table No.1 and 2 to EEP-ROM. The values are
written to EEP-ROM and therefore stored even if
the power is switched off.
The decimal value converted from the lower two
digits of the code No. corresponds to the point table
No.
8F01h
Deceleration time constant data EEP-ROM
to
command of point table
8F02h
Writes the deceleration time constants of point
table No.1 and 2 to EEP-ROM. The values are
written to EEP-ROM and therefore stored even if
the power is switched off.
The decimal value converted from the lower two
digits of the code No. corresponds to the point table
No.
Item
17 - 20
Writing data (RW
(Programmable controller→Servo amplifier)
Convert the values into hexadecimal before setting.
Convert the values into hexadecimal before setting.
Convert the values into hexadecimal before setting.
Convert the values into hexadecimal before setting.
Convert the values into hexadecimal before setting.
Convert the values into hexadecimal before setting.
+3) contents