17. SPEED CONTROL OPERATION
Code No.
0081h
Energization time
Reads the energization time from shipment.
0082h
Power on frequency
Reads the number of power-on times from
shipment.
00A0h
Load to motor inertia ratio
Reads the estimated load to motor inertia ratio to
servo motor shaft inertia moment.
00C0h
Error parameter No./Point data No. reading
Reads the parameter No./point table No. in error.
Item/Function
Reading data (RW
(Servo amplifier→programmable controller)
Returns the energization time [h].
Cumulative energization time
Returns the number of power-on times.
Power on frequency
Return unit [times]
Ratio of load inertia moment
Parameter No. or point table No.
Parameter group
0: Basic setting parameters (No.PA
1: Gain/filter parameters (No.PB
2: Extension setting parameters (No.PC
3: I/O setting parameters (No.PD
Type
1: Parameter
2: Point table
17 - 17
+3) contents
rn
)
)
)
)