Selection Of Regenerative Option - Mitsubishi Electric MELSERVO-J3 Series Instruction Manual

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

6. PARAMETERS

6.1.4 Selection of regenerative option

No.
Symbol
PA02
*REG
Regenerative option
Set this parameter when using the regenerative option, brake unit, power regeneration converter, or power
regeneration common converter.
Parameter No.PA02
0 0
Parameter
Name
POINT
This parameter is made valid when power is switched off, then on after
setting.
Wrong setting may cause the regenerative option to burn.
If the regenerative option selected is not for use with the servo amplifier,
parameter error (A37) occurs.
Selection of regenerative option
00: Regenerative option is not used
For servo amplifier of 100W, regenerative resistor is not used.
For servo amplifier of 200 to 7kW, built-in regenerative resistor is used.
Supplied regenerative resistors or regenerative option is used with
the servo amplifier of 11k to 22kW.
01: FR-BU2-(H) FR-RC-(H) FR-CV-(H)
02: MR-RB032
03: MR-RB12
04: MR-RB32
05: MR-RB30
06: MR-RB50(Cooling fan is required)
08: MR-RB31
09: MR-RB51(Cooling fan is required)
80: MR-RB1H-4
81: MR-RB3M-4(Cooling fan is required)
82: MR-RB3G-4(Cooling fan is required)
83: MR-RB5G-4(Cooling fan is required)
84: MR-RB34-4(Cooling fan is required)
85: MR-RB54-4(Cooling fan is required)
FA: When the supplied regenerative resistor or the regenerative option
is cooled by the cooling fan to increase the ability with the servo
amplifier of 11k to 22kW
6 - 4
Initial
Unit
Setting range
value
0000h
Refer to the text.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents