4.5.4 Power supply

Signal
Digital I/F power supply
input
Digital I/F common
Open collector power input
Control common
Shield

4.6 Detailed description of signals (devices)

4.6.1 Forward rotation start reverse rotation start temporary stop/restart

(1) A forward rotation start (RYn1) or a reverse rotation start (RYn2) should make the sequence which can be
used after the main circuit has been established. These signals are invalid if it is switched on before the
main circuit is established.
Normally, it is interlocked with the ready signal (RD).
(2) A start in the servo amplifier is made when a forward rotation start (RYn1) or a reverse rotation start (RYn2)
changes from OFF to ON. The delay time of the servo amplifier's internal processing is max. 3ms. The
delay time of other devices is max. 10ms.
Forward rotation start (RYn1)
or reverse rotation start (RYn2)
Temporary stop/Restart (RYn7)
(3) When a programmable controller is used, the ON time of a forward rotation start (RYn1), a reverse rotation
start (RYn2) or temporary start/stop (RYn7) signal should be 6ms or longer to prevent a malfunction.
(4) During operation, the forward rotation start (RYn1) or reverse rotation start (RYn2) is not accepted. The
next operation should always be started after the rough match (RXn2) is output with the rough match output
range set to "0" or after the movement completion (RXnC) is output.
Connector
Symbol
pin No.
DICOM
CN6-5
Used to input 24VDC (24VDC 10% 150mA) for I/O interface. The
power supply capacity changes depending on the number of I/O
interface points to be used.
Connect the plus of 24VDC terminal external power supply for the
sink interface.
DOCOM
CN6-17
Common terminal for input signals such as DOG and EMG. Pins are
connected internally. Separated from LG.
Connect the plus of 24VDC terminal external power supply for the
source interface.
OPC
CN6-18
When using the MR-HDP01 manual pulse generator, connect OPC
and DICOMD, and supply OPC with the positive ( ) voltage of
24VDC.
LG
CN6-23
Common terminal for the differential line driver of the encoder pulses
(LA LAR LB LBR LZ LZR).
SD
Plate
Connect the external conductor of the shield cable.
Forward
rotation
Servo motor speed
0r/min
Functions/Applications
3ms or less
10ms
or less
6ms or more
4 - 30
3ms or less
I/O
division

Hide quick links: