6. PARAMETERS
No.
Symbol
PC19 *ENRS Encoder output pulse selection
Use to select the encoder output pulse direction and encoder output pulse
setting.
0 0
Set value
0
1
Encoder output pulse setting selection (refer to parameter No.PA15).
0: Output pulse designation
1: Division ratio setting
2: Ratio is automatically set to command pulse unit
Setting "2" makes the parameter No.PA15 (encoder output pulse)
setting invalid.
PC20
*SNO
Station number setting
Used to specify the station number of the servo amplifier for RS-422
communication.
Always set one station to one axis of servo amplifier. If one station number
is set to two or more stations, normal communication cannot be made.
PC21
*SOP
RS-422 communication function selection
Select the communication I/F and select the RS-422 communication
conditions.
0
PC22 *COP1 Function selection C-1
Select the encoder cable communication system selection.
0
Name and function
Encoder output pulse phase changing
Changes the phases of A, B-phase encoder output
pulses.
Servo motor rotation direction
CCW
A-phase
B-phase
A-phase
B-phase
0
RS-422 communication baud rate selection
0: 9600
[bps]
1: 19200 [bps]
2: 38400 [bps]
3: 57600 [bps]
4: 115200[bps]
RS-422 communication response delay time
0: Invalid
1: Valid, reply sent after delay time of 800 s or more
0
0
Encoder cable communication system selection
0: Two-wire type
1: Four-wire type
Incorrect setting will result in an encoder alarm 1
(A16) or encoder alarm 2 (A20).
CW
A-phase
B-phase
A-phase
B-phase
6 - 25
Initial value
Unit
Setting range
0000h
name and
0
station
0000h
name and
0000h
Refer to the
name and
Refer to
function
column.
0
to
31
Refer to
function
column.
function
field.