4. SIGNALS AND WIRING

4.12 Grounding

WARNING
The servo amplifier switches the power transistor on-off to supply power to the servo motor. Depending on the
wiring and ground cable routing, the servo amplifier may be affected by the switching noise (due to di/dt and
dv/dt) of the transistor. To prevent such a fault, refer to the following diagram and always ground.
To conform to the EMC Directive, refer to the EMC Installation Guidelines (IB(NA)67310).
MCCB
(Note)
Power supply
Note. For 1-phase 200 to 230VAC or 1-phase 100 to 120VAC, connect the power supply to L
There is no L
for 1-phase 100 to 120VAC power supply. Refer to section 1.2 for the power supply specification.
3
Ground the servo amplifier and servo motor securely.
To prevent an electric shock, always connect the protective earth (PE) terminal
(terminal marked
) of the servo amplifier with the protective earth (PE) of the
control box.
Control box
MC
Protective earth (PE)
Servo amplifier
CN2
L
1
L
2
L
3
L
U
11
L
21
V
W
CN3
4 - 57
Servo motor
Encoder
U
V
M
W
Ensure to connect it to PE
terminal of the servo amplifier.
Do not connect the wire directly
the protective earth of
the cabinet.
L
and leave L
open.
1
2
3