Mitsubishi Electric MELSERVO-J3 Series Instruction Manual page 737

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

17. SPEED CONTROL OPERATION
No.
Symbol
PC23
PC24
PC25
PC26
*COP5 Function selection C-5
PC27
PC28
PC29
PC30
*DSS
PC31
PC32
PC33
PC34
PC35
TL2
PC36
PC37
PC38
Name and function
For manufacturer setting
Do not change this value by any means.
Not used in speed control operation.
Do not change the parameter.
For manufacturer setting
Do not change this value by any means.
Select the stroke limit warning (A99).
0 0 0
Stroke limit warning(A99) selection
0: Valid
1: Invalid
When "1" is set, A99 will not occur
if the forward rotation stroke end (LSP) or
reverse rotation stroke end (LSN) turns off.
For manufacturer setting
Do not change this value by any means.
Not used in speed control operation.
Do not change the parameter.
For manufacturer setting
Do not change this value by any means.
Remote register-based speed specifying method selection
This parameter is made valid when the speed specifying method selection
(RY(n+2)A) is turned on with 2 stations occupied. Select how to receive a
speed command.
When 1 station is occupied, selecting "0100" will result in a parameter error.
0
0 0
Setting
0
1
Not used in speed control operation.
Do not change the parameter.
Internal torque limit 2
Set the parameter on the assumption that the maximum torque is 100 [%].
The parameter is for limiting the torque of the servo motor.
No torque is generated when this parameter is set to "0".
For manufacturer setting
Do not change this value by any means.
Not used in speed control operation.
Do not change the parameter.
Speed command
Specifying the speed selection No.
Specifying the servo motor speed
17 - 52
Initial
Setting
Unit
value
Range
0000h
0000h
0000h
0000h
Refer to
the
Name
and
function
column.
0000h
0000h
0000h
0000h
Refer to
the
Name
and
function
column.
0
0
100.0
%
0
to
100.0
0000h
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents