Functions 12. I/O Remote Settings
12.2.4 Timing Diagram for Safety Door Input Sequence
SafeguardOn
(*1) A logical signal to explain the timing of internal processing of the controller.
12.2.5 Timing Diagram for Emergency Stop Sequence
(*1) A logical signal to explain the timing of internal processing of the controller.
134
Running
Output
Paused
Output
Output
MotorsOn
Output
SD Signal
(*1)
SDLATCH
Signal (*1)
Continue
Input
For details about input signals name and operating conditions, refer to the 9.3 Pin
Assignments.
Running
Output
MotorsOn
Output
EStopOff
Output
ESW Signal
(*1)
Reset Signal
Input
For details about input signals name and operating conditions, refer to the 9.3 Pin
Assignments.
1052
1052
9
8
500
920
7
5
11
11
928
[Unit: msec]
7
[Unit: msec]
RC700-D Rev.2