Epson RC700-D Manual page 42

Robot controller
Table of Contents

Advertisement

Installation 2. Installation
Safety Door Switch
WARNING
In order to maintain a safe working zone, a safeguard must be set up around the Manipulator.
The safeguard must have an interlock switch at the entrance to the working zoon. The
Safety Door that is described in this manual is one of the safeguards and an interlock of the
Safety Door is called a Safety Door switch. Connect the Safety Door switch to the Safety
Door input terminal on the EMERGENCY connector.
The Safety Door switch has safety features such as temporary hold-up of the program or
the operation-prohibited status that are activated whenever the Safety Door is opened.
Observe the following in designing the Safety Door switch and the Safety Door.
- For the Safety Door switch, select a switch that opens as the Safety Door opens, and not
by the spring of the switch itself.
- The signal from the Safety Door (Safety Door input) is designed to input to two redundant
signals. If the signals at the two inputs differ by two seconds or more, the system regards
it as a critical error. Therefore, make sure that the Safety Door switch has two separate
redundant circuits and that each connects to the specified pins at the EMERGENCY
connector on the Controller.
- The Safety Door must be designed and installed so that it does not close accidentally.
Latch Release Switch
Software latches state of safety door opened/closed and state of TEACH mode.
The EMERGENCY connector has an input terminal for a latch release switch that cancels
the latched conditions.
Open
Closed : The latch release switch releases the latched conditions.
When the latched TEACH mode is released while the safety door is open, the status of
NOTE
Manipulator power is operation-prohibited because the safety door is open at that time.
To execute a Manipulator operation, close the safety door again, and then close the latch
release input.
26
The interlock of the Safety Door must be functioning when the
robot system is operated. Do not operate the system under the
condition that the switch cannot be turned ON/OFF (e.g. covering
the switch with tape). Operating the robot system when the
switch is not functioning properly is extremely hazardous and
may cause serious safety problems as the Safety Door input
cannot fulfill its intended function.
:The latch release switch latches conditions that the safety door is open or the
operation mode is "TEACH".
RC700-D Rev.2

Advertisement

Table of Contents
loading

Table of Contents