The FlexCut 200 does not come with an SO cord
installed for the main power connection. Use
a
three-phase supply line. A 1.75 inch (45
mm) diameter access hold for the input supply is
located on the case back.
Connect L1, L2, L3 and ground per connection
diagrams and National Electric Code.
To access the input power connection block,
remove the seven screws and the left case side
of the machine as shown.
Connections between the FlexCut 200 and FlexCool 35:
1.
Connect the 115v from the FlexCool 35 to the 115v connection
on the back of the FlexCut 200.
2. Connect the ARCLINK cable from the FlexCut 200 to the
FlexCool 35.
3.
The two coolant supply lines from the FLEXSTART box will
be coming out the cable carrier. Attach the supply lines to
the FlexCool 35.
4. On the gantry by the FLEXSTART box, remove the zip tie
and connect the two hoses and ARCLINK barrel connector to
the FLEXSTART.
FROM
COOLER
FROM
POWER
SOURCE
TO
STAR
GROUND
FLEXSTART boxes are mounted to the gantry on the 5100.
Hoses and cables are run into the cable carrier.
Input Cord Strain Relief:
Route input cord through
relief and twist nut to tighten.
Ground Connection:
Connect Ground Lead per local
and national electrical codes
115 V
AC**
TO
FLEXSTART
ix
Power Connection Block:
Connect each phase of a three
phase connector here
ARC LINK
User Guide