Machine Faults:
Problem
WATER LEVEL LOW is illuminated. The water cannot
be raised any higher.
Constant Z-Axis following error on attempted DATUM
Large "backlash" symptom in X Axis.
Oblong holes.
Laser Faults:
Problem
An error message occurs when attempting to turn
the Laser on stating "The laser cannot be activated
in Active Run"
The laser does not appear to be landing where the
centerline of the torch would be on the material
LOGIN as ADMIN, under the WATER FILL TAB, follow the
steps to add sufficient water to the table.
Check brake relay connection & double terminated pin at
servo drive.
Verify motor cable connections.
Remove X cover and evaluate belt condition. Loosen the
motor bolts and tighten tension screw to proper tension.
Tighten motor bolts.
Toggle the system to Dry Run mode.
Reset the Z axis. If a larger error is reported, the laser
position would be off. Enter the material thickness
decimal equivalent, and turn the laser off and back on
again.