Lincoln Electric TORCHMATE 5100 User Manual page 23

Hide thumbs Also See for TORCHMATE 5100:
Table of Contents

Advertisement

Power to Plasma:
The plasma power supply chosen requires 3-phase electrical connections and numerous other connections
needed by your specific power supply to interface with the machine; consult the specific plasma power
supply's user manual for more details.
Depending on the particular model plasma cutter, an input power cord may not be included.
Fuse the input circuit with the recommended super lag fuses or delay type breakers. Choose input and
grounding wire size according to local or national electric codes. Using input wire sizes, fuses, or circuit
breakers smaller than recommended may result in "nuisance" shut-offs from high inrush currents, even if the
machine is not being used at high currents.
Connection to the supply circuit can be by means of flexible supply cables or supply cables through conduit to
a permanent installation. The supply cables should have a 600 volt minimum rating and be sized according to
local and national codes.
FineLine® 170HD:
FineLine® 300HD:
FlexCut® 125:
FlexCut® 200:
Voltage
380-415V / 3 / 50/60
460V / 3 / 50/60
575V / 3 / 50/60
Voltage
380-415V / 3 / 50/60
460V / 3 / 50/60
575V / 3 / 50/60
Voltage
380-415V / 3 / 50/60
460V / 3 / 50/60
575V / 3 / 50/60
Voltage
380-415V / 3 / 50/60
460V / 3 / 50/60
575V / 3 / 50/60
11
Input Ampers
Fuse (Super Lag) or
Breaker Size
69
58
53
Input Ampers
Fuse (Super Lag) or
Breaker Size
123
108
95
Input Ampers
Fuse (Super Lag) or
Breaker Size
40
33
22
Input Ampers
Fuse (Super Lag) or
Breaker Size
71
63
55
2
80
70
60
2
150
125
100
2
50
40
30
2
80
70
60
User Guide

Advertisement

Table of Contents
loading

Table of Contents