When commissioning your new table, it is recommened to cut the same quatity test cut included with the machine
to validate similar output. This quality check test cut is included with the machine for comparison.
The proper consumables for the factory test cut are preloaded into the torch prior to shipping.
Torchmate 5100

Quality Test Cut

1.
Press SELECT JOB.
2.
Locate the appropriate g-code for your machines configuration and
press OK.
3.
Set the Plasma Console to Steel, the thickness to 3/16", and the
Current to 80 amps. The proper Cut Parameters are populated in the
inputs.
4.
5100 Inline test cut will now show in the display.
5.
Set Cut Parameters to Program Defined.
6.
Set the AVHC MODE to AUTO.
7.
Set the SAMPLE VOLTAGE to ON.
8.
Set the IHS (ohmic detection) to ON.
9.
Set the IHS MODE to ALWAYS.
10.
Set the Machine to Active Run (If Dry Run is displayed, press once to
toggle to Active Run)
11.
Verify that the FEED RATE OVERRIDE is set to 100%