Lincoln Electric TORCHMATE 5100 User Manual page 55

Hide thumbs Also See for TORCHMATE 5100:
Table of Contents

Advertisement

Quality Test Cut:
If you need to stop the
machine at any time
please hit the stop
button on the touch
screen.
4.550
10.
Set the Machine to Active Run (If Dry Run is displayed, press once to
toggle to Active Run)
11.
12.
PRESS RUN JOB. This will move the torch to the plate and start
the job.
(PLASMA TORCH WILL FIRE! WEAR APPROPRIATE EYE PROTECTION.)
13.
The sample cut includes a plasma marked '5100' feature then
processes the inside features. The code switches the plasma to
marking and populates the settings.
Rapid travel to the first inside feature
Z Axis moves toward the material, touching the top of the
material (IHS -ohmic detection)
Torch retracts to set PIERCE HEIGHT and will fire and starts the
program.
Once the marking is complete, the plasma will switch to cut all
inside features first, then move to the outside geometry
Once cut is complete, compare the cut to the provided sample and verify that
they match. This will provide proof that the machine is functioning properly.
NOTE: Part will be hot after cutting. Wear proper gloves prior to handling the
processed cut.
5.000 ±.032
6.000 ±.032
43